Make Patch Cable Rj45

Step 1: Before we start building our patch cable, you will need to cut a length of Cat6 cable. When cutting your cable be certain to make the correct measurements as.

The RJ45 CAT5e Patch Cable is perfect for use with 10/100Base-T networks.

How to Make Cat 5 / 5e Patch Cables DIY article. All the information you should need to build straight through Cat 5 Patch Cables and Crossover Cat 5 Patch Cables.

How to make a cat 6 patch cable. got questions. we ve got answers. call right now 866-738-8993. we gurantee a lifetime of customer service and competitive pricing.

make patch cable rj45

20 items  Mediabridge Cat5e Ethernet Patch Cable 10 Feet - RJ45 Computer Networking Cord - Blue - Aurum Cables Flat Cat6 Snagless Network Ethernet Patch Cable.

How to Make a Category 5 / Cat 5E Patch Cable make patch cable rj45 Select Cable By Color

LANshack.comwas the very first e-commerce website to offer free online tutorials for cable connections. To say that our articles have been popular over the span of many years would be an understatement. But time marches on and we now have three major updates. For one, we have updated this very popular tutorial, and two, we now have a video tutorial to go with it. But most importantly, we have now developed a totally new system for termination cables called the QuickTreX PRO System.

Before you begin, you should know which wiring scheme you will be using. The only difference between 568A and 568B wiring is that pairs 2 and 3 orange and green are swapped. If you are unsure which one to use then you should go with the 568B diagram. It is the 568B diagram that we demonstrate in this tutorial and the 568A wiring is shown in the diagrams below mainly for illustration. In our estimation the 568B connection is used in over 99 of all straight through applications. Know that using either the A or B standard will produce a straight through connection that should work for any Ethernet or POE power over Ethernet application. Therefore do not sweat over the choice.

For more Information see: Controversies and Caveats: Category 5, 5E, and Cat 6 Patch Cables below.

Application Note: To make a crossover patch cable, you should wire one end 568B and the other end 568A

How to make a Cat 5 or Cat 6 Patch Cable: Install RJ-45 Connectors: Easy Loadbar Method

Below are the steps outlined in the video. Once you get good at it, with some dexterity the assembly time will be less than a minute.

1 Start at about 1.5 to 2 back on the cable and skin the cable s jacket. Circle the cable with the tool 1-2 times.

2 Remove the stripper tool and gently bend the cable where it was scored by the tool in both directions back and forth. The cable s outer jacket should just pull off.

4 Use the discarded piece of the cable s jacket to complete the process. Leave about 1 twist at the end.

5 Straighten out the wires. Use of a blunt edge tool like a long nose pliers will help greatly and save your fingers.

6 Refer to the diagram that you intend to use. In this case, we are using the 568B scheme.

7 Put the wires in the appropriate order and get them as straight and close together as possible by running them through your fingers

8 While holding the group of wires in perfect fashion, cut off about 0.25 from the end to get the wires ready to go into the loadbar.

Tip:Be sure to hold the wires tightly or you may have to do the process all over.

Tip:We strongly recommend using a sharp pair of Electricians Scissors to make the cuts. Using a cutting plier can flatten the ends making it impossible to get the wires into the holes of the loadbar.

We recommend the Award Winning Wire Surgeon Scissors for this task.

9 Insert the wires into the loadbar with the hollow end of the loadbar facing the wires. Slide the loadbar down on the wires

Tip:Gently jiggle the wires from side to side while maintaining pressure on the bundle and they will all come through easily.

Tip:Check the sequence of the colors once again before you proceed to the next step.

10 Put the wire assembly over a connector so that the jacket is about 1/8 into the connector. Then mark the wire at the point where it is even with the end of the connector.

11 Use the electrician s wire scissors to cut the wires straight across at the point where you made the mark.

12 With the Orange pair furthest away from you and the Brown pair closest, slide the connector on to the assembly with the pins facing up and the locking clip facing down. Push the assembly into the connector with a slight wiggling motion to make the ends of the wires go all the way to the end of the connector. It may be necessary to use moderately firm pushing to make this happen. At this point it is advisable to use a magnifying glass or jeweler s loop to look directly into the face of the connector to see that the wires have gone all the way in.

13 Insert the connector into the crimper and keep pressure on the cable pushing it in to the connector until the crimp is complete. Use a high quality Industry Standard Crimper such as our QuickTreX Professional Five In One Modular Crimping Tool

14 If you intend to use cable boots, slide them onto the cable now before installing the opposite connector. Boots are completely optional.

15 Repeat the process and install the connector on the opposite end.

16 Test the cable with a 4-pair type Cable Tester.

Thank you for visiting LANshack.com and viewing our tutorial. Get all the tools you ll need to get the job done. Take advantage of these special offers found only on our tutorials:

Get everything you need to terminate a Cat 5e modular plug.

Tool Case:These tool cases are great looking while being virtually indestructible.

Datacomm Hand Tools:Professional Grade Crimpers, Termination tools, Wire Strippers, Wire and Kevlar Scissors, etc.

Test and Trace:Pro-Basic LAN cable tester with remote.

Cat 5e Modular Plugs with Loadbars.

Perfect for Category 5 and Category 5 Enhanced applications. Bag of 100 pieces.

LAN TEST-PRO II Cable Tester with 8 Remotes

The graphical interface with Length Test will simplify troubleshooting, and take away the guess work.

Notes Regarding Making Category 5 Patch Cable

1 The RJ-45 plugs are normally made for either solid conductors or stranded conductors. It is very important to be sure that the plug that you use matches the conductor type. It is extremely difficult to tell the difference between the two by looking at them. When you buy these plugs, be sure to categorize, and store them carefully. Using the wrong type can cause intermittent problems. The QuickTreX Category 5E, 8 Conductor Modular Plugs, OR QuickTreX Category 6, 8 Conductor Modular Plugsthat we sell are rated for both Solid and Stranded cable.

2 Ordinarily, it would be taboo to untwist the pairs of any category 5 or 6 cable. The one exception to this rule is when crimping on RJ-45 plugs. It would be impossible to insert the wires into the channels without first untwisting and straightening them. Be sure not to extend the un-twisting, past the skin point. If you do it properly, you will wind up with no more than 1/2 of untwisted conductors up to 1/2 of untwist meets the cat 5 or 6 specification.

3 If the completed assembly does not pass continuity, you may have a problem in one, or both ends. First try giving each end another crimp. If that does not work, then carefully examine each end. Are the wires in the proper order. Do all of the wires fully extend to the end of the connector. Are all of the pins pushed down fully. Cut off the suspected bad connector, and re-terminate it. If you still have a problem, then repeat the process, this time giving more scrutiny to the end that was not replaced.

Controversies And Caveats: Category 5, 5E, And Cat 6 Patch Cables

For patch cables, 568-B wiring is by far, the most common wiring method. Virtually all pre-assembled patch cables are wired to the B standard. There is no difference in connectivity between 568B and 568A cables. Therefore, a 568B patch cable should work fine on a 568A cabling system, and visa-versa.

We have seen this happen time and time again. Perfectly good patch cables that have been working fine for years, get removed from their installation, and re-installed on the same, or different network. The result can be a nightmare. What happens is that the cable, over time, adapts to the way that it is bent in it s original installation. When these cables are removed and re-installed, they can either completely lose their connection, or develop intermittent problems. This is due to stresses that may be opposite to what they were originally subject to. If the integrity of your network is more valuable than the price of new patch cables, then we strongly suggest that you use brand new cables for all closet cleanups, network moves, etc.

Almost all patch cables that are made have stranded wire. Stranded wire is normally specified for use in patch cables due to its superior flexibility. There has been some talk recently, in the technical sector of the structured wiring community, regarding the possible use of solid conductors for patch cables. The reason for the spotlight on solid wire is that it is supposedly more stable, under a variety of conditions. Please note that we now offer custom Solid copper category 5E patch cables in Plenuminsulation in lengths of up to 295 feet. These cables are suitable for use in air handling Plenum ceilings and environments.

Wiring Crossover Cables. So now it s time for the crossover cables. They are a bit harder to make than standard patch cables, you ll need to follow the wiring.

How to Make a Category 5 / Cat 5E Patch Cable. Did you know. LANshack.com was the very first e-commerce website to offer free online tutorials for cable connections.